The LUGG new generation isolatable replaceable anti-vibration inductive vortex flowmeter adopts an integrated housing structure with stable mechanical performance and minimized leakage risks. Equipped with an isolatable sensor, it supports online sensor replacement without pipeline flow shutdown. The sensor features excellent anti-vibration, ultra-high pressure resistance and ultra-high temperature resistance. The built-in signal spectrum scanning processing circuit of the transmitter further optimizes anti-vibration capability, delivering the advantages of wide turndown ratio, low minimum measuring flow velocity and low operating pressure loss.
Applicable to a variety of harsh working conditions, this product has been widely recognized by customers since its launch, providing reliable flow measurement solutions for high-temperature and strong-vibration industrial scenarios.
Product Features
- Safe and leak-proof: No sealing parts or compression screws are adopted, ensuring an integral leak-free structure.
- Online non-stop flow replacement: Sensors can be replaced online without cutting off medium flow, avoiding huge production losses caused by shutdown maintenance and realizing dual operational safety guarantee.
- Ultra-wide temperature resistance: Applicable medium temperature ranges from 350℃ to 550℃.
- Ultra-high pressure resistance: Rated pressure covers 2.5MPa, 45MPa and 64MPa.
- Excellent anti-vibration performance: Effectively resists vibration interference of 0.5g to 2.0g.
- Low minimum flow velocity: Gas: 1.98m/s ~ 1.2m/s; Liquid: 0.21m/s ~ 0.18m/s. The gas flow velocity of 1.98m/s and liquid flow velocity of 0.21m/s are achieved under the working pressure of 2.03MPa.
- Wide turndown ratio: Optional ratios of 10:1, 20:1, 35:1 and 40:1.
- Complete product specifications: Available with single signal output, dual signal output and four-channel signal output. Multiple safety protections ensure safe, stable and uninterrupted detection and control operation.
Technical Parameters
| Item | Performance Parameters |
|---|
| Nominal Diameter | Full pipe type: DN15~DN400; Insertion type: ≥DN200 |
| Nominal Pressure | 1.6MPa, 2.5MPa, 4.0MPa; customized higher pressure available |
| Medium Temperature | Standard type: -40℃~+250℃; High-temperature type: -40℃~+550℃ |
| Body Material | 304 stainless steel; special materials available on customized order |
| Accuracy Grade | Full pipe type: ±0.5%, ±1.0%, ±1.5%; Insertion type: ±2.5% |
| Turndown Ratio | 1:10 ~ 1:35 |
| Power Supply | External power: 24VDC±15% (for 4~20mA, pulse, RS485 signal); Internal power: 3.6V lithium battery, continuous service life of more than 1 year |
| Signal Output | 4~20mA analog signal, pulse signal |
| Communication Output | RS485 communication, HART protocol |
| Ambient Conditions | Ambient temperature: -20℃~+60℃; Relative humidity: 5%~90% |
| Explosion-proof Grade | ExdbIIB T4...T6 Gb |
| Protection Grade | IP65, IP67, IP68 |
Remarks
Dual-vibrator manufacturing process can be adopted for special working conditions.
Flow Range